Power cords & plugs:
American UL Power cords
Australia SAA Power cords
British BS Power cords
Europe VDE Power cords
North America Power cords
Japan PSE Power cords
Korea KTL Power cords
Italy IMQ Power cords
South Africa Power cords
Sweitzerland SE Power cords
France NF Power cords
Denmark D Power cords
No-Mark products
  Rubber Products
Rubble cable
Industry Extension Cable
German Extension Cable
Locking Extension Cable
  PVC Cable & Extension Cords:
VDE Extension Cable
Outdoor Extension Cable
N-America Extension Cable
  Industry Cable Reel
  Other Cable Reel
  Power Cord Reference
  New Products
PVC CABLE--- CCC
 227 IEC 52(RVV)-300/300V
CONDUCTOR
INSULATION
JACKET
No.of core
sectional area(mm 2 )
Nom.Thick.(mm)
Nom.Diam.(mm)
Nom.Thick.(mm)
Nom.Diam.(mm)
2
0.5
0.5
1.95
0.6
5.2
0.5
1.95
3.25×5.20
0.75
2.15
5.6
0.75
2.15
3.60×5.75
3
0.5
1.95
5.6
0.75
2.15
5.9
 227 IEC 53(RVV)-300/500V
CONDUCTOR
INSULATION
JACKET
No.of core
sectional area (mm 2 )
Nom.Thick. (mm)
Nom.Diam.(mm)
Nom.Thick. (mm)
Nom.Diam.(mm)
2
0.75
0.6
2.35
0.8
6.3
0.75
0.6
2.35
0.8
4.0×6.4
1.0
0.6
2.55
0.8
6.8
1.5
0.7
3.00
0.8
7.8
3
0.75
0.6
2.35
0.8
6.5
1.0
0.6
2.55
0.8
7.1
1.5
0.7
3.00
0.9
8.3
 227 IEC 53(YZ)/57(YZW)-300/500V
CONDUCTOR
INSULATION
JACKET
WIRE EXRADIUS
No.of core
sectional area (mm 2 )
Nom.Thick. (mm)
Nom.Diam.(mm)
LTM DOME.(mm)
LTM DOME.(mm)
2
0.75
0.6
0.8
6.0
8.2
1.0
0.6
0.9
6.6
8.8
1.5
0.8
1.0
8.0
10.5
0.75
0.6
0.8
6.5
8.8
3
1.0
0.6
0.9
7.0
9.2
1.5
0.8
1.0
8.6
11.0
PVC POWER SUPPLY CORDS --- VDE
 H05RR-F/H05RN-F



CONDUCTOR
INSULATION
JACKET
WIRE EXRADIUS
No.of core
sectional area (mm2)
Nom.Thick. (mm)
Nom.Thick.(mm)
LTM DOME(mm)
LTM DOME(mm)
2
0.75
0.6
0.8
6.0
8.2
1.0
0.6
0.9
6.6
8.8
1.5
0.8
1.0
8.0
10.5
2.5
0.9
1.1
9.5
12.5
3
0.75
0.6
0.9
6.5
8.8
1.0
0.6
0.9
7.0
9.2
1.5
0.8
1.0
8.6
11.0
2.5
0.9
1.1
10.0
13.0
4
0.75
0.6
0.9
7.1
9.6
1.0
0.6
0.9
7.6
10.0
1.5
0.8
1.1
9.6
12.5
2.5
0.9
1.2
11.0
14.0
5
0.75
0.6
1.0
8.0
11.0
1.0
0.6
1.0
8.5
11.5
1.5
0.8
1.0
10.5
13.5
2.5
0.9
1.3
12.5
15.5
 H07RN-F
CONDUCTOR
INSULATION
JACKET
WIRE EXRADIUS
No.of core
sectional area (mm2)
Nom.Thick. (mm)
Nom.Thick.(mm)
LTM DOME(mm)
LTM DOME(mm)
2
1.0
0.8
1.3
8.0
10.5
1.5
0.8
1.5
9.0
11.5
2.5
0.9
1.7
10.5
13.5
3
1.0
0.8
1.4
8.6
11.5
1.5
0.8
1.6
11.5
12.5
2.5
0.9
1.8
0.8
14.5
4
1.0
0.8
1.5
9.6
12.5
1.5
0.8
1.7
10.5
13.5
2.5
0.9
1.9
12.5
15.5
5
1.0
0.8
1.6
10.5
13.5
1.5
0.8
1.8
11.5
15
2.5
0.9
2.0
13.5
17
PVC POWER SUPPLY CORDS --- UL/CSA
  SPT-1
CONDUCTOR
INSULATION
JACKET
AMP RATING
AWG Size
sectional area (mm2)
Nom.Thick. (mm)
Nom.Diam. (mm)
Nom.Thick.
(mm)
Nom.Diam.
(mm)
18
0.82
-
-
0.76
2.70×5.35
10A
18
0.82
0.76
2.0
0.76
2.70×8.30
10A
 SPT-2
18
0.82
-
-
1.14
3.50×6.95
10A
16
1.31
-
-
1.14
3.75×7.55
13A
18
0.82
0.38
2.15
1.14
3.60×9.50
10A
16
1.31
0.38
2.40
1.14
4.00×10.4
13A
  SVT
CONDUCTOR
INSULATION
JACKET
AMP RATING
AWG Size
sectional area (mm2)
Nom.Thick. (mm)
Nom.Diam.(mm)
Nom.Thick. (mm)
Nom.Diam.(mm)
18
0.82
0.38
2.05
0.76
5.90
10A
17
1.03
0.38
2.20
0.76
6.20
12A
16
1.31
0.38
2.30
0.76
6.40
13A
18
0.82
0.38
2.5
0.76
6.25
7A
17
1.03
0.38
2.20
0.76
6.60
9A
16
1.31
0.38
2.30
0.76
6.80
13A
  SJT/SJTW/SJTO/SJTOW
CONDUCTOR
INSULATION
JACKET
AMP RATING
AWG Size
sectional area (mm2)
Nom.Thick. (mm)
Nom.Diam.(mm)
Nom.Thick. (mm)
Nom.Diam.(mm)
18
0.82
0.76
2.80
0.76
7.25
10A
16
1.31
0.76
3.10
0.76
7.80
13A
14
2.08
0.76
3.50
4.00
8.70
15A
12
3.31
0.76
4.00
1.14
10.30
20A
18
0.82
0.76
2.80
0.76
7.8
7A
16
1.31
0.76
3.10
0.76
8.4
10A
14
2.08
0.76
3.50
1.14
9.30
15A
12
3.31
0.76
4.00
1.52
11.0
20A
18
0.82
0.76
2.80
0.76
8.45
7A
16
1.31
0.76
3.10
0.76
9.20
10A
14
2.08
0.76
3.50
0.76
10.20
15A
12
3.31
0.76
4.00
1.14
12.10
20A
PVC POWER SUPPLY CORDS --- SAA
  250/250 FLAT FLEXIBLE CORDS SAA
CONDUCTOR
INSULATION
JACKET
No.of core
sectional area (mm 2 )
Nom.Thick. (mm)
Nom.Diam.(mm)
Nom.Thick. (mm)
Nom.Diam.(mm)
2
0.5
0.8
-
-
3.0×5.7
0.75
0.8
-
-
3.3×6.3
 250/440 FLAT FLEXIBLE CORDS
2
0.5
0.6
-
-
4.2×6.3
0.75
0.6
-
-
4.6×7.0
 250/440 ORDINARY DUTY FLEXIBLE CORDS
CONDUCTOR
INSULATION
JACKET
No.of core
sectional area (mm 2 )
Nom.Thick. (mm)
Nom.Diam.(mm)
Nom.Thick. (mm)
Nom.Diam.(mm)
2
0.75
0.6
2.35
0.8
7.0
1.0
0.6
2.55
0.8
7.2
1.5
0.7
3.00
0.8
8.2
3
0.75
0.6
2.35
0.8
7.4
1.0
0.6
2.55
0.8
7.0
1.5
0.7
3.00
0.9
8.9
 227 IEC 53(RVV)-300/500V SAA
CONDUCTOR
INSULATION
JACKET
No.of core
sectional area (mm 2 )
Nom.Thick. (mm)
Nom.Diam.(mm)
Nom.Thick. (mm)
Nom.Diam.(mm)
2
0.75
0.8
2.55
1.3
8.8
1.0
0.8
2.75
1.3
9.0
1.5
0.8
3.20
1.5
10.1
3
0.75
0.8
2.55
1.4
9.5
1.0
0.8
2.75
1.4
9.8
1.5
0.8
3.20
1.6
10.8
4
0.75
0.8
2.55
1.5
10.5
1.0
0.8
2.75
1.5
10.7
1.5
0.8
3.20
1.7
11.8
XUANHUA 2000-2007 ALL RIGHTS RECEIVED T:0086-574-62160890 ;F: 0086-574-62162585
E-MAIL::nbxh2005@yahoo.com.cn